Selective
Data
| Model |
Capacity
(gpm)
S |
Media
Volume
(ft³)
S |
Capacity
(gpm)
MM |
Media
Volume
(ft³)
MM |
Capacity
(gpm)
AC |
Media
Volume
(ft³)
AC |
Capacity
(gpm)
BM |
Media
Volume
(ft³)
BM |
Filter
dia
(in) |
Pipe
Size
(in) |
| VF-30 |
20 |
7 |
50 |
15 |
50 |
16 |
20 |
15 |
30 |
2 |
| VF-36 |
30 |
10 |
70 |
21 |
70 |
22 |
30 |
21 |
36 |
2 |
| VF-42 |
40 |
12 |
90 |
29 |
90 |
30 |
40 |
29 |
42 |
2 |
| VF-48 |
50 |
16 |
120 |
38 |
120 |
40 |
50 |
38 |
48 |
3 |
| VF-60 |
80 |
26 |
190 |
60 |
190 |
62 |
80 |
60 |
60 |
3 |
| VF-66 |
95 |
32 |
240 |
70 |
240 |
72 |
95 |
70 |
66 |
4 |
| VF-72 |
110 |
37 |
280 |
85 |
280 |
89 |
110 |
85 |
72 |
4 |
| VF-78 |
130 |
44 |
330 |
100 |
330 |
105 |
130 |
100 |
78 |
4 |
| VF-84 |
150 |
50 |
380 |
115 |
380 |
118 |
150 |
115 |
84 |
6 |
|
|
|
|
 |
S=Sand,
MM = Multi Media, AC = Activated Carbon,
BM = Birm
|
 |
Design
Pressure = 100 psig
|
 |
Carbon
Steel vessels are designed with welded
dish heads.
|
 |
The
above specifications apply to
vertical pressure vessels. Horizontal pressure vessels are
available from 48 inch diameter and above.
|
 |
Larger
capacities are available.
|
 |
Electric
characteristics for automatic systems:
220 V, 1 PH, 60 HZ as standard
(110 V, 3 PH, 50 HZ available)
|
 |
Environment:
ambient temperature less than 50ºC,
and shielded from direct sunlight.
|
|
|
|
|
   
|
|
|
|
|
|